Quantcast
Channel: Zenoss Community: Message List
Browsing all 783 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

Zenoss Modeling restarting Cisco Wireless AP

Hi, I have an issue with Zenoss Core 4.2.0 . When I add a Cisco Aironet 2602E AP to the devices and Zenoss models the devices, the device restarts. This unfortunately does not only happen on the...

View Article


About the job PENDING

Hi all, the problem is as the title. When I add the device from the web UI, the state of the job is alway PENDING. At last, I restart the zenoss daemons. Why does not the job's state change from...

View Article


Unable to view component for HRSWInstalledMap on ZenOSS UI after modeling.

After modeling device for HRSWInstalledMap modeler, I am able to get data for the device which consist of Product key and installed date in the backend.But I am unable to see component for...

View Article

"Model Time" significance when running modelers

Kindly help me to get the details of the below queries : (1)  What does "Model time" mean ?          1>  Is it  the time when device modelling was initiated or         2>  When device was...

View Article

Re: Infrastructure in tact however no events appearing

Errors in the winperf log: 2014-02-18 05:05:31,397 WARNING zen.winperf.PerfRpc: Bad counter for device 172.20.75.201: \LogicalDisk(\\?\Volume{f4f1740e-c7c4-11df-9dbf-806e6f6e6963})\% Disk Write Time...

View Article


Moving Zenoss to a new server

Recently I have installed zenoss on a new server and would like to take the backup of my current zenoss instance and load it on to the new instance. Both the new and the old server are centos 6 servers...

View Article

Email Allerts issues Zenoss core 4.2.4

Hi all, having issues with setting email alerts. looks like i cant get email alerts to more than one "notifications" if set up a few triggers and set them up with email notifications. - this works......

View Article

Image may be NSFW.
Clik here to view.

Monitoring OID without graphing

Hello All, I'm new to Zenoss and SNMP monitoring, so bare with me . I have a couple of APC UPS's that I would like to monitor an OID that shows the battery output status. I'm having a hard time trying...

View Article


Re: Monitoring OID without graphing

Please use the new forums athttp://www.zenoss.org/forums/community-zenoss-support

View Article


Image may be NSFW.
Clik here to view.

Question in the way a graph displays

I am sorry if this is easly found somewhere. In the below graph does the k mean kilo and m mean milli? Or am I off on that thinking. Thanks for your help, Keith

View Article

Zenoss and DNS lookups

Hi, I've had serveral issues caused by the fact that Zenoss doesn't automatically refresh DNS and IPs on hosts. I know I can do it manually via "Actions" -> "Reset IP". I know how to do this via...

View Article

Trigger bug!

Hi, I have ZenOSS 4.2.4 installed on CentOS 6.5 x64. I found 2 bugs (i think), hope it is not a bug and you can help me fix it:  After creting a trigger I double click on the trriger or clicking the...

View Article

FindPosKeyError script issue

Over the last couple weeks, I've had a number of devices coming up with POSKeyError messages. I discovered the "FindPosKeyError.py" script that was available on...

View Article


Re: FindPosKeyError script issue

For the record, I'm still running on 4.2.3. Planning to do an upgrade soon, but would prefer to do a clean upgrade with no errors in the database or errors in device relationships, etc.

View Article

Auto-discovery in zenoss 4.2.

Auto-discovery in zenoss commercial version 4.2.1.  Does auto-discovery in zenoss run automatically?          If yes          A.  How often does auto-discovery run, by default?          B.  Is there a...

View Article


Image may be NSFW.
Clik here to view.

Mail alert template (made by me)

Hey everyone, I was working to make Zenoss mail notification be more "fancy". After some html modifications here is the result: See attached file to get the html code, just copy and paste in your...

View Article

Error 1045 While installing Zenoss 4.2.4

Hello All, I am trying to install Zenoss 4.2.4, and I am receiving the following error message: Fresh install pre stepsChecking RRDtool version >=1.4.7: [ OK ] 1.4.7Error 1045 (28000): Access denied...

View Article


POSKeyError - unable to delete a device

Type: <class 'ZODB.POSException.POSKeyError'>Value: 0x01efd4 Traceback (most recent call last):  File "/opt/zenoss/lib/python/ZPublisher/Publish.py", line 126, in publish    request, bind=1)...

View Article

Image may be NSFW.
Clik here to view.

Zenoss 4.2.3 Custom Report Error

Hello, I have created a custom report in Zenoss 4.2.3 for inventory but I am not able to get output at all. Instead another session on Infrastructure opens inside the report. Following is the report...

View Article

Zenrestore command restores everything that is available in backup file. It...

Zenrestore command restores everything that is available in backup file. It ignores the options provided with the zenrestore command.  We tried restoring backup using --no-zodb and --no-perfdata...

View Article
Browsing all 783 articles
Browse latest View live